Inspection Detail
Inspection: 651430 - Ncr Corporation, Microelectronics Division
Inspection Information - Office: Denver Area Office
Site Address:
Ncr Corporation, Microelectronics Division
1635 Aeroplaza Drive
Colorado Springs, CO 80916
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3674
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 04/04/1986
Emphasis:
Case Closed: 05/20/1986
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360633812 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 2 | 3 | |||
| Current Violations | 1 | 2 | 3 | |||
| Initial Penalty | $240 | $0 | $0 | $0 | $0 | $240 |
| Current Penalty | $240 | $0 | $0 | $0 | $0 | $240 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100038 A05 III | 04/07/1986 | 05/12/1986 | $240 | $240 | $0 | - | ||
| 2. | 01001B | Serious | 19100134 B08 | 04/07/1986 | 05/12/1986 | $0 | $0 | $0 | - | ||
| 3. | 02001 | Other | 19100132 A | 04/07/1986 | 06/02/1986 | $0 | $0 | $0 | - | ||
| 4. | 02002A | Other | 19100134 B01 | 04/07/1986 | 05/12/1986 | $0 | $0 | $0 | - | ||
| 5. | 02002B | Other | 19100134 B03 | 04/07/1986 | 05/12/1986 | $0 | $0 | $0 | - | ||
| 6. | 02002C | Other | 19100134 B11 | 04/07/1986 | 05/01/1986 | $0 | $0 | $0 | - | ||
| 7. | 02002D | Other | 19100134 E03 | 04/07/1986 | 06/02/1986 | $0 | $0 | $0 | - | ||
| 8. | 02002E | Other | 19100134 E05 I | 04/07/1986 | 05/12/1986 | $0 | $0 | $0 | - | ||
| 9. | 02002F | Other | 19100134 E05 I | 04/07/1986 | 05/12/1986 | $0 | $0 | $0 | - | ||
| 10. | 02002G | Other | 19100134 F02 II | 04/07/1986 | 05/12/1986 | $0 | $0 | $0 | - |
Investigation Summary
THE AFFECTED EMPLOYEES WERE EXPOSED TO PHOSPHINE GAS DURING THE OPERATION OF AN ION IMPLANTER. THE GASES FROM INSIDE THE VACUUM CHAMBER WERE EMITTED INTO THE WORK ENVIRONMENT BECAUSE THE VENTILATION CONNECTION ON THE VACUUM PUMP WAS NOT ATTACHED TO THE VENTILATION SYSTEM.
Keywords: RESPIRATORY, VENTILATION, INHALATION, PHOSPHINE GAS, TOXIC FUMES
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 651430 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 2 | 651430 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 3 | 651430 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 4 | 651430 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 5 | 651430 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 6 | 651430 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 7 | 651430 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 8 | 651430 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 9 | 651430 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 10 | 651430 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 11 | 651430 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 12 | 651430 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported |
Translate