Inspection Detail
Inspection: 316618255 - Meadwestvaco Corporation
Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation
Site Address:
Meadwestvaco Corporation
5255 Virginia Ave
North Charleston, SC 29406
Mailing Address:
, , 00000
Union Status: Union
SIC:2861
NAICS: 325191/Gum and Wood Chemical Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 12/10/2012
Planning Guide: Health-Manufacturing
Emphasis:
Case Closed: 01/11/2013
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102667516 |
Investigation Summary
On September 24, 2012, Employee #1, a shipping worker, was unloading a tank, which was located next to a 400,000 gallon storage tank (Tank Number 10) of crude tall oil. Process fluids from the tall oil distillation were redirected to this storage tank due to a pump failure on the T-3 column. The flow meter for the process reverted to its factory settings. This change in flow caused the operator to falsely believe that the line was plugging and in response turned up the heat to the Doyle & Roth T-3 preheater. The difference in the set point of the flow meter and the actual flow caused a control valve to close reducing the amount of process fluid to twenty percent of its normal flow rate. The T-3 preheater, due to the loss of flow rate, heated the process fluids to the auto ignition point. The tank of crude tall oil erupted and caught fire and caused an explosion. Employee #1 was taken to the hospital as a precautionary measure after he tripped and fell when the tank exploded.
Keywords: FIRE, LUBRICATING FLUID, EXPLOSION, TRIPPED, FALL, TANK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 316618255 | Non Hospitalized injury | Bruise/Contus/Abras | Material recording, sched'g & distr. clerks n.e.c. |