Inspection Detail
Inspection: 315479220 - Independent Drilling, Inc.
Inspection Information - Office: Jacksonville Area Office
Site Address:
Independent Drilling, Inc.
3009 Old Archer Road
Gainesville, FL 32608
Mailing Address:
110 Satelite Court, Leesburg, FL 34748
Union Status: NonUnion
SIC:1481
NAICS: 541360/Geophysical Surveying and Mapping Services
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/28/2011
Emphasis: S:Electrical
Case Closed: 10/07/2011
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101358588 |
Investigation Summary
An employee was taking bore samples when the hand auger that he was using contacted an underground power line. The employee was electrocuted.
Keywords: ELECTRICAL, ELECTROCUTED, AUGER, UNDRGRD POWER LINE, E GI IB
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 315479220 | Fatality | Electric Shock | Occupation not reported |
Translate