Inspection Detail
Inspection: 312567266 - Anotex Industries, Inc.
Inspection Information - Office: Cincinnati Area Office
Site Address:
Anotex Industries, Inc.
4914 Rialto Road
Westchester, OH 45069
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3479
NAICS: 332812/ Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/14/2008
Emphasis:
Case Closed: 12/31/2008
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101962546 | ||
| Referral | 201955556 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 4 | ||||
| Current Violations | 4 | 4 | ||||
| Initial Penalty | $4,500 | $0 | $0 | $0 | $0 | $4,500 |
| Current Penalty | $2,000 | $0 | $0 | $0 | $0 | $2,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100106 E02IV C | 11/20/2008 | 12/17/2008 | $500 | $1,500 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19100132 A | 11/20/2008 | 12/17/2008 | $500 | $1,500 | $0 | I - Informal Settlement | ||
| 3. | 01003 | Serious | 19101200 E01 | 11/20/2008 | 01/09/2009 | $500 | $750 | $0 | I - Informal Settlement | ||
| 4. | 01004 | Serious | 19101200 H01 | 11/20/2008 | 01/09/2009 | $500 | $750 | $0 | I - Informal Settlement |
Investigation Summary
At approximately 1:00 p.m. on October 30, 2008, Employee #1 was burned in a flash fire and died from his injuries. Employee #1 was using Miccro Super XP-2000, a Class 1B flammable liquid (FP 38 degrees F (TCC) and 0 degrees F (test method); BP of 215 degrees F; Vapor Density 1.0) to coat the heads of bolts. Employee #1 would pour the liquid from a five-gallon container with a plastic nozzle directly into a small container from which a small brush could be dipped in and the substance painted on the bolt heads. There were no witnesses to the event and it is unknown if Employee #1 spilled or overfilled the small container from the five-gallon container and the ignition source is unknown. There are no special precautions or demarcated areas relative to electrical sparking potential from equipment or system wiring. A cigarette lighter was found in the area of the flash fire. However, a coworker indicated that Employee #1 was not a smoker. The Employer noted that other employees do smoke, but were not supposed to smoke in the building he said, but they may do so behind his back. There were no signs prohibiting smoking and there was no indication that a smoking prohibition was effectively enforced.
Keywords: BURN, POURING, FLAMMABLE LIQUID, FLAMMABLE VAPORS, FIRE, SMOKING
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 312567266 | Fatality | Burn/Scald(Heat) | Laborers, except construction |