Inspection Detail
Inspection: 308315324 - Grey Wolf. Inc.
Inspection Information - Office: Houston South Area Office
Site Address:
Grey Wolf. Inc.
3718 Stratton Bridge Rd
Clute, TX 77351
Mailing Address:
10370 Richmnd Ave Ste.600, Houston, TX 77042
Union Status: NonUnion
SIC:1381
NAICS: 213111/Drilling Oil and Gas Wells
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/27/2005
Emphasis:
Case Closed: 06/27/2005
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101931657 |
Investigation Summary
On June 7, 2005, Employee #1 was setting up a portable steam cleaner that was powered by a portable generator. After plugging the cleaner's power cord into the generator, he picked up the hose and wand, which was energized. Employee #1 was electrocuted.
Keywords: STEAM CLEANER, CLEANING, ELECTROCUTED, EQUIPMENT FAILURE, HOSE, SET UP, ELECTRIC GENERATOR
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 308315324 | Fatality | Electric Shock | Occupation not reported |