Inspection Detail
Inspection: 1549748.015 - Olon Ricerca Bioscience, Llc
Inspection Information - Office: Cleveland Area Office
Site Address:
Olon Ricerca Bioscience, Llc
7528 Auburn Road
Painesville, OH 44077
Mailing Address:
7528 Auburn Road, Painesville, OH 44077
Union Status: NonUnion
SIC:
NAICS: 541715
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/25/2021
Emphasis: P:Piv, L:Piv
Case Closed: 03/07/2022
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1801512 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 7 | 7 | ||||
| Current Violations | 7 | 7 | ||||
| Initial Penalty | $61,446 | $0 | $0 | $0 | $0 | $61,446 |
| Current Penalty | $39,935 | $0 | $0 | $0 | $0 | $39,935 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100147 C06 I C | 11/15/2021 | 01/03/2022 | $5,705 | $8,778 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19100303 E01 II | 11/15/2021 | $5,705 | $8,778 | $0 | I - Informal Settlement | |||
| 3. | 01003A | Serious | 19100303 H05 III A | 11/15/2021 | $5,705 | $8,778 | $0 | I - Informal Settlement | |||
| 4. | 01003B | Serious | 19100303 H05 III B | 11/15/2021 | $0 | $0 | $0 | I - Informal Settlement | |||
| 5. | 01004 | Serious | 19100332 B03 | 11/15/2021 | 01/03/2022 | $5,705 | $8,778 | $0 | I - Informal Settlement | ||
| 6. | 01005 | Serious | 19100333 A02 | 11/15/2021 | 01/03/2022 | $5,705 | $8,778 | $0 | I - Informal Settlement | ||
| 7. | 01006 | Serious | 19100334 C03 | 11/15/2021 | $5,705 | $8,778 | $0 | I - Informal Settlement | |||
| 8. | 01007 | Serious | 19100335 A01 I | 11/15/2021 | $5,705 | $8,778 | $0 | I - Informal Settlement |
Investigation Summary
At 1:30 p.m. on August 22, 2021, an employee working as an operations and maintenance technician for a bioscience research facility was troubleshooting an electrical system. The employee was investigating a power outage in Building B. The employee and a coworker, the facility supervisor, began troubleshooting the outage. The employee reset a switch in the outdoor substation, but the power did not return. The employee attempted to take a reading on one of the four lines that comes from the substation to an indoor 4160-Volt 6-Amp feeder. The feeder is located at Unit Substation 4 located in the penthouse of Building B. The employee opened a medium voltage transformer to access a switch located in the metal enclosed electrical cabinet to take a reading on the fuses when he caused an arc flash/blast. The employee was not wearing proper personal protective equipment, using proper electrical tools and had not received proper training in the high voltage electrical work. The employee was hospitalized to treat electrical shock and burns to his chest, arms, hands and fingers.
Keywords: Arm, Burn, Chest, Conductor, Electric Arc, Electric Arc Flash, Electric Shock, Electrical, Electrical Box, Electrical Burn, Electrical Cabinet, Electrical Wire, Electrical Work, Engineering Controls, Finger, Hand, Lack of Engineering Controls, Lack of Work Procedures, Lockout, Lockout/Tagout, Maintenance, PPE, PPE Hazard Assessment, Protective Clothing, Shock, Technician, Training, Transformer, Troubleshooting, Wrong Equipment
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1549748.015 | 53 | M | Hospitalized injury |
Translate