Inspection Detail
Inspection: 1444488.015 - Kinder Morgan Inc
Inspection Information - Office: Iowa 0751910
Site Address:
Kinder Morgan Inc
21864 120th St
Columbus Junction, IA 52738
Mailing Address:
21864 120th St, Columbus Junction, IA 52738
Union Status: NonUnion
SIC:
NAICS: 486210/Pipeline Transportation of Natural Gas
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/13/2019
Emphasis:
Case Closed: 12/17/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1516655 | Yes |
Investigation Summary
At 1:15 p.m. on November 7, 2019, an employee wroking for a natural gas plant was balancing a gas injection engine. The employee was descending a 6-foot ladder when he misjudged his step to the next rung. The employee slipped off the ladder and fell to the concrete floor below. The employee landed on his right leg fracturing his tibia and requiring hospitalization.
Keywords: Concrete Floor, Descending, Descending Ladder, Fall, Fall From Elevation, Fracture, Gas Generator, Lack of Engineering Controls, Ladder, Leg, Misjudgment, Misjudgment of Hazardous Situation, Natural Gas, Slip, Tibia, Work Surface
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1444488.015 | 46 | M | Hospitalized injury | Laborers, except construction |