Inspection Detail
Inspection: 1423256.015 - Chemical Distributors, Inc.
Inspection Information - Office: Buffalo Area Office
Site Address:
Chemical Distributors, Inc.
80 Metcalfe Street
Buffalo, NY 14206
Mailing Address:
80 Metcalfe Street, Buffalo, NY 14206
Union Status: NonUnion
SIC:
NAICS: 424690/Other Chemical and Allied Products Merchant Wholesalers
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 08/14/2019
Emphasis:
Case Closed: 10/24/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1486020 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $6,763 | $0 | $0 | $0 | $0 | $6,763 |
| Current Penalty | $3,725 | $0 | $0 | $0 | $0 | $3,725 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100132 A | 09/24/2019 | 10/02/2019 | $3,725 | $6,763 | $0 | I - Informal Settlement |
Investigation Summary
At 9:00 a.m. on August 6, 2019, an employee was reconnecting a motor to a drum pump. The drum pump was still plugged into the electrical outlet. When the employee reconnected the motor his hand brushed the toggle switch and hydrofluoric acid pumped out onto him. The employee was hospitalized to treat hydrofluoric acid burns to the groin and upper leg.
Keywords: Chemical Burn, Connecting, Groin, Hydrofluoric Acid, Leg, Outlet
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1423256.015 | 35 | M | Hospitalized injury | Laborers, except construction |
Translate