Inspection Detail
Inspection: 1344003.015 - Precast Wall Systems, Inc.
Inspection Information - Office: Fort Lauderdale Area Office
Site Address:
Precast Wall Systems, Inc.
1199 W. Lantana Road
Lake Worth, FL 33462
Mailing Address:
1888 Nw 22nd Court, Pompano Beach, FL 33069
Union Status: NonUnion
SIC:
NAICS: 238120/Structural Steel and Precast Concrete Contractors
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/05/2018
Emphasis: L:Ohpwrlne
Case Closed: 04/15/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1378304 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 1 | 3 | |||
| Current Violations | 2 | 1 | 3 | |||
| Initial Penalty | $15,912 | $0 | $0 | $0 | $0 | $15,912 |
| Current Penalty | $11,140 | $0 | $0 | $0 | $0 | $11,140 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19261408 B01 | 03/04/2019 | 04/12/2019 | $6,498 | $9,282 | $0 | I - Informal Settlement | ||
| 2. | 01001B | Serious | 19261410 D01 | 03/04/2019 | 04/12/2019 | $0 | $0 | $0 | I - Informal Settlement | ||
| 3. | 01002A | Serious | 19261408 G01 I | 03/04/2019 | 04/12/2019 | $4,642 | $6,630 | $0 | I - Informal Settlement | ||
| 4. | 01002B | Serious | 19261430 B | 03/04/2019 | 04/12/2019 | $0 | $0 | $0 | I - Informal Settlement | ||
| 5. | 02001 | Other | 19261408 A01 | 03/04/2019 | 04/12/2019 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
On September 4, 2018, Employees #1 and #2 and coworkers, employed by a precast concrete construction company, were using a crane to install concrete wall panels into previously installed concrete columns for a new building. The crane's load line made contact with energized overhead power lines while Employees #1 and #2 were guiding the wall panels by hand. The two employees sustained electric shocks of 7,620 volts to multiple areas of their bodies. Emergency services transported the employees to the hospital, where they were admitted for treatment.
Keywords: Burn, Concrete Panel, Construction, Contact, Crane, Electric Shock, Electric current, Energized, Installing, Load Line, Overhead Power Line
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1344003.015 | 39 | M | Hospitalized injury | Construction Laborer | |