Inspection Detail
Inspection: 126126838 - Howard Appliances
Inspection Information - Office: Monrovia District Office
Site Address:
Howard Appliances
4177 Rowland Ave
El Monte, CA 91731
Mailing Address:
901 E Imperial Hwy, La Habra, CA 90631
Union Status: NonUnion
SIC:5722
NAICS: 443111/Household Appliance Stores
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/20/2005
Emphasis:
Case Closed: 07/18/2006
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362597791 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | ||||||
| Initial Penalty | $18,000 | $0 | $0 | $375 | $0 | $18,375 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203 A | 07/20/2005 | 08/22/2005 | $0 | $375 | $0 | 11/09/2005 | F - Formal Settlement | Citation has been deleted. |
| 2. | 02001 | Serious | 23200002 A04 | 07/20/2005 | 08/22/2005 | $0 | $18,000 | $0 | 11/09/2005 | F - Formal Settlement | Citation has been deleted. |
Investigation Summary
At 2:00 p.m. on March 23, 2005, an employee was working as an electronics technician in the television and appliance service department of a retail store. He had worked for the company for 23 years. He was servicing a microwave oven that needed a new magnetron tube. With the power to the oven still on, he lifted the oven. His hand accidentally came into contact with a power connection to the oven's magnetron tube. The oven's power supply provided current to the magnetron at 4,000 volts DC. The employee sustained an electric shock and lacerated the index finger on his right hand. He was hospitalized seven days for treatment.
Keywords: E GI IV, ELECTRICAL, LOCKOUT, LACERATION, ELEC CIRC PART--MISC, ELECTRIC SHOCK, MICROWAVE OVEN, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 126126838 | Hospitalized injury | Electric Shock | Electrical and electronic technicians |
Translate