Site Address:
American Fruit Processor
10725 Sutter Ave.
Pacoima, CA 91331
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2037
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/06/2001
Emphasis:
Case Closed: 05/31/2001
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362516510 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $485 | $0 | $485 |
| Current Penalty | $0 | $0 | $0 | $485 | $0 | $485 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3383 A | 03/06/2001 | 03/30/2001 | $485 | $485 | $0 | - |
Investigation Summary
On November 29, 2000, an accident occurred at American Fruit Processors. Employee #1, a sanitation worker, had hooked up a portable hose to a stainless steel washout line to wash out a fill tank in the fruit processing plant. The heat exchanger pumped hot water at approximately 40 psi through the pipe and hose into another pipe that went into the top of the tank. At the end of the pipe was a spray head that sprayed the hot water into the tank to clean it. The portable flexible hose was used to go around a sharp corner and connect with the clean out pipe. The flexible hose was rated for approximately 300 psi and was connected by a union that was bolted to the hose with a bracket. This union then mated up with the union on the clean-out pipe. The employee hooked up the hose, and the pump was turned on. Employee #1 was standing in front of the connection when the hose came loose from the fitting and hot water sprayed the employee's legs. The employee was taken to Maxi-Medical Center for emergency treatment. He was treated and released, but later developed complications and checked himself into a hospital.
Keywords: BURN, FOOD PREPARATION, AGRICULTURE, HOSE, LINE CONNECTOR, STRUCK BY, HOT WATER, LEG
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120309331 | Hospitalized injury | Burn/Scald(Heat) | Laborers, except construction |