Inspection Detail
Inspection: 109467415 - U.S. Dept. Of Army
Inspection Information - Office: Raleigh Area Office
Site Address:
U.S. Dept. Of Army
Materiel Maintenance Div
Fort Bragg, NC 28307
Mailing Address:
, , 00000
Union Status: Union
SIC:9711
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: Y
Ownership:
Safety/Health: Safety
Close Conference: 08/29/1995
Emphasis:
Case Closed: 02/01/1996
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360955587 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 7 | 1 | 3 | 11 | ||
| Current Violations | 7 | 1 | 3 | 11 | ||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100106 E06 I | 11/01/1995 | 11/06/1995 | $0 | $0 | $0 | - | ||
| 2. | 01002 | Serious | 19100107 B09 | 11/01/1995 | 11/06/1995 | $0 | $0 | $0 | - | ||
| 3. | 01003 | Serious | 19100107 D02 | 11/01/1995 | 11/06/1995 | $0 | $0 | $0 | - | ||
| 4. | 01004 | Serious | 19100107 E04 | 11/01/1995 | 11/06/1995 | $0 | $0 | $0 | - | ||
| 5. | 01005 | Serious | 19100107 E09 | 11/01/1995 | 11/06/1995 | $0 | $0 | $0 | - | ||
| 6. | 01006 | Serious | 19100307 B | 11/01/1995 | 11/06/1995 | $0 | $0 | $0 | - | ||
| 7. | 01007 | Serious | 19101200 H02 II | 11/01/1995 | 12/19/1995 | $0 | $0 | $0 | - | ||
| 8. | 02001 | Willful | 19100107 C05 | 11/01/1995 | 11/06/1995 | $0 | $0 | $0 | - | ||
| 9. | 03001 | Other | 19600055 A | 11/01/1995 | 12/19/1995 | $0 | $0 | $0 | - | ||
| 10. | 03002 | Other | 19600058 | 11/01/1995 | 12/19/1995 | $0 | $0 | $0 | - | ||
| 11. | 03003 | Other | 19600059 A | 11/01/1995 | 12/19/1995 | $0 | $0 | $0 | - |
Investigation Summary
On July 19, 1995, Employees #1 and #2, painters, were applying 791 peelable booth coating, a class 1B flammable liquid, with an airless sprayer inside a large paint spray booth. The paint sprayer was not explosion-proof and was not approved to be used in this location. All the doors to the spray booth were closed and the ventilation system was not turned on. One of the employees was operating the spray gun while the other employee helped. After approximately 45 to 60 minutes, an explosion and fire occurred inside the booth, killing Employees #1 and #2.
Keywords: BURN, VENTILATION, FLAMMABLE LIQUID, WORK RULES, FIRE, SPRAY PAINTING, EXPLOSION, PAINTER, SPRAY BOOTH
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 109467415 | Fatality | Burn/Scald(Heat) | Occupation not reported | ||
| 2 | 109467415 | Fatality | Burn/Scald(Heat) | Occupation not reported |
Translate