Violation Detail
Standard Cited: 19100430 C01 III Equipment.
Inspection Nr: 1757758.015
Citation: 02007
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/09/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0420300
Contest Date:
Final Order: 01/08/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/08/2025 | $0.00 | Other | ||
| Penalty | Z: Issued | 12/09/2024 | $0.00 | Serious |
Text For Citation: 02 Item/Group: 007 Hazard:
29 CFR 1910.430(c)(1)(iii): Breathing gas supply hose(s) were not tested at least annually to 1.5 times their working pressure: On or about June 25, 2024, supplied air to the divers had not been tested at least annually to 1.5 times the air hose working pressure, thereby exposing the divers to a drowning hazard in 19 feet deep water.