Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1403977.015
Citation: 02003A
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/28/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/23/2019
Gravity:
Report ID: 0418300
Contest Date:
Final Order: 11/18/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/18/2019 | $0.00 | 12/23/2019 | Other | |
| Penalty | Z: Issued | 10/28/2019 | $0.00 | 11/22/2019 | Other |
Text For Citation: 02 Item/Group: 003A Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) On or about May 28, 2019 - Facility, employees were exposed to struck-by and electrical hazards when the machine specific lockout/tagout procedures for equipment such as, but not limited to, the Pack Mack Bagger, Cutting Vat Dump, and the Bag Take Away Conveyor did not include specific instructions for shutting down and securing the equipment.
Translate