Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1495253.015
Citation: 02001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $8,290.00
Current Penalty: $1,740.00
Issuance Date: 03/18/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 04/06/2021
Gravity: 5
Report ID: 1032500
Contest Date:
Final Order: 04/14/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/14/2021 | $1,740.00 | 04/06/2021 | Other | |
| Penalty | Z: Issued | 03/18/2021 | $8,290.00 | 04/06/2021 | Serious |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy: a) Mozzarella Packaging, Line #11: On September 25, 2020, the "Lockout Tag Out Procedure, Shutdown For S Conveyor to Line 11, PR-SOR-1288, Rev A, 08/01/12" was not specific to the tasks of daily cleaning and sanitation work where a guard is removed and workers may be exposed to moving parts. Note) Certification of corrective action is required for this item.