Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1453302.015
Citation: 02001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/07/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 04/29/2020
Gravity:
Report ID: 0419400
Contest Date:
Final Order: 05/19/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/19/2020 | $0.00 | 04/29/2020 | Other | |
| Penalty | Z: Issued | 04/07/2020 | $0.00 | 04/29/2020 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Injection Mold - On or about December 23, 2019 the employer had not performed a lockout audit to determine if the program was working.