Violation Detail
Standard Cited: 19100179 J02 Overhead and gantry cranes.
Inspection Nr: 1434174.015
Citation: 02001
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $1,190.00
Current Penalty: $1,190.00
Issuance Date: 02/25/2020
Nr Instances: 1
Nr Exposed: 6
Abatement Date:
Gravity:
Report ID: 0419700
Contest Date:
Final Order: 03/12/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/12/2020 | $1,190.00 | Other | ||
| Penalty | Z: Issued | 02/25/2020 | $1,190.00 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.179(j)(2): The items listed in subparagraphs (j)(2)(i)-(vii) were not inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, and all deficiencies were not carefully examined and a determination made as to whether they constituted a safety hazard: a. On or about September 18, 2019, the daily inspection of the 125 Log Crane did not include examination or testing of the upper limit switch functionality and a determination of the safety hazard.
Translate