Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1699781.015
Citation: 01004
Citation Type: Serious
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $4,839.00
Current Penalty: $3,387.30
Issuance Date: 01/16/2024
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 02/09/2024
Gravity: 10
Report ID: 0728900
Contest Date:
Final Order: 02/23/2024
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/23/2024 | $3,387.30 | 02/09/2024 | Serious | |
| Penalty | Z: Issued | 01/16/2024 | $4,839.00 | 02/09/2024 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: Employees engaged in re-roofing operations located at 842 South Kansas Ave, Hastings, Nebraska 68901, were being exposed to fall hazards in that an extension ladder being used for access and egress to and from the roof did not extend at least 3ft above the upper landing surface.