Violation Detail
Standard Cited: 19100146 D01 Permit-required confined spaces
Inspection Nr: 1799909.015
Citation: 01003D
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/16/2025
Nr Instances: 3
Nr Exposed: 3
Abatement Date: 09/02/2025
Gravity: 10
Report ID: 0112600
Contest Date: 08/05/2025
Final Order:
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | C: Contested | 08/22/2025 | $0.00 | 09/02/2025 | Serious | |
| Penalty | Z: Issued | 07/16/2025 | $0.00 | 09/02/2025 | Serious |
Text For Citation: 01 Item/Group: 003D Hazard:
29 CFR 1910.146(d)(1): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not implement the measures necessary to prevent unauthorized entry: 194 Cleveland St. Greenfield, MA: On or about January 24, 2025, and at times prior, the employer did not prevent unauthorized entry into permit-required confined spaces when two employees entered a material storage bin in an attempt to rescue an engulfed employee, and were exposed to engulfment and asphyxiation hazards.