Violation Detail
Standard Cited: 19100147 D04 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1568871.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $13,052.00
Current Penalty: $13,052.00
Issuance Date: 03/22/2022
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0214200
Contest Date: 04/11/2022
Final Order:
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | C: Contested | 04/13/2022 | $13,052.00 | Serious | ||
| Penalty | Z: Issued | 03/22/2022 | $13,052.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d)(4):Lockout or tagout device application. The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): Location: 147 Clinton Rd. West Caldwell, NJ 07006 - Turkey Processing Room a) Employees exposed to caught in hazards; employees conducting meat cleaning operations on a on a Tipper Tie Stuffing Machine RS4204 with a Fluid Flow A3 Metal Detector and Fortress Stealth WD Type 4 conveyor system attached without applying safe Lock out Tag out application device which led to an incident which occurred on or about 12/13/21.