Violation Detail
Standard Cited: 19100219 F03 Mechanical power-transmission apparatus.
Inspection Nr: 1450605.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,566.00
Current Penalty: $11,566.00
Issuance Date: 03/03/2020
Nr Instances: 12
Nr Exposed: 2
Abatement Date: 03/20/2020
Gravity: 5
Report ID: 0625400
Contest Date:
Final Order: 04/01/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/01/2020 | $11,566.00 | 03/20/2020 | Serious | |
| Penalty | Z: Issued | 03/03/2020 | $11,566.00 | 03/20/2020 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: On or about December 5, 2019, and at times prior thereto, the tops of chains and sprockets used to provide power to multiple motorized rotating shafts in the Roof Line Area were unguarded, exposing employees to the hazard of getting caught in rotating parts.