Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
Inspection Nr: 1322933.015
Citation: 01002
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $9,239.00
Current Penalty: $1,000.00
Issuance Date: 11/13/2018
Nr Instances: 2
Nr Exposed: 4
Abatement Date: 11/21/2018
Gravity:
Report ID: 0627700
Contest Date:
Final Order: 12/06/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/06/2018 | $1,000.00 | 11/21/2018 | Other | |
| Penalty | Z: Issued | 11/13/2018 | $9,239.00 | 11/21/2018 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one-half inch: The employer does not ensure industrial floor fans are provided with guards that have openings no greater than one-half inch, exposing employees to amputation hazards. a) This violation was observed on or about June 11, 2018, in the forward wire draw area, where a large industrial box fan had openings in the guarding measured approximately 1 inch by 2.5 inches. b) This violation was observed on or about June 11, 2018, in the forward wire draw area, where a large industrial box fan had openings in the guarding measured approximately 2 inches by 2.5 inches.
Translate