Violation Detail
Standard Cited: 19261408 G01 I
Inspection Nr: 1183236.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,183.00
Current Penalty: $2,928.10
Issuance Date: 02/16/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 03/08/2017
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 04/19/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/19/2017 | $2,928.10 | 03/08/2017 | Serious | |
| Penalty | Z: Issued | 02/16/2017 | $4,183.00 | 03/08/2017 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.1408(g)(1)(i): The employer had not train the each employee and crew member assigned to work with the equipment in the procedures to be followed in the event of electrical contact with a power line. Such training must include: 1926.1408(g)(1)(i) A through F. On or about 10/12/2016 at the Moss Creek Estates lot 51, Alpharetta, GA: At this job site, employees engaged in and preparing to elevate wooden trusses and other wooden material with the Manitex Hydraulic Boom Truck Crane was exposed to an electrical contact while working near the live overhead power lines rated at about 119.15KV. The employer had not trained the each operator or crew member on the procedures to be followed in the event of electrical contact with a power line. On 10/12/2016 one employee was fatality injured and another employee was seriously injured when the crane equipment including rigging equipment came in contact with the live overhead power lines.