Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1513505.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/27/2021
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 08/31/2021
Gravity: 10
Report ID: 0418300
Contest Date:
Final Order: 08/19/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/19/2021 | $0.00 | 08/31/2021 | Serious | |
| Penalty | Z: Issued | 07/27/2021 | $0.00 | 08/20/2021 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: (a) On or about 01/29/2021 - Fabrication Area, authorized employees were exposed to caught-between hazards when performing servicing and maintenance activities such as, but not limited to, adjusting proximity switch sensors on the Trumpf Tru-Laser 5030 Automatic Pallet Changer and the machine had not been shut down as required in the written lockout procedure "Trumpf - Tru-Laser 5030 (A0231A0314)".