Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1436853.015
Citation: 01001C
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $9,282.00
Current Penalty: $0.00
Issuance Date: 11/08/2019
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 11/19/2019
Gravity:
Report ID: 0627700
Contest Date:
Final Order: 12/04/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/04/2019 | $0.00 | 11/19/2019 | Other | |
| Penalty | Z: Issued | 11/08/2019 | $9,282.00 | 11/19/2019 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage. This violation occurred on or about October 3, 2019, and at times prior thereto, employees were not required to shut off the main control panel for the chopper machine when unjamming the cyclones exposing employees to struck-by and caught-in hazards.