Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1424427.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/19/2019
Nr Instances: 1
Nr Exposed: 8
Abatement Date: 01/17/2020
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 10/16/2019
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/16/2019 | $0.00 | 01/17/2020 | Serious | |
| Penalty | Z: Issued | 09/19/2019 | $0.00 | 10/18/2019 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Production Floor; On or about August 12, 2019 energy isolating devices were not operated in such a manner as to isolate the Rotoflex die cutter from energy source(s) while an employee worked inside of the machine performing adjustments. (b) Production Floor; Energy isolating devices were not operated in such a manner as to isolate the Rotoflex, CEI, and Mark Andy die cutters from energy source(s) while employees worked inside of the machine performing adjustments.