Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1360258.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $6,000.00
Issuance Date: 04/11/2019
Nr Instances: 1
Nr Exposed: 30
Abatement Date: 05/09/2019
Gravity: 10
Report ID: 0521100
Contest Date:
Final Order: 05/06/2019
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/06/2019 | $6,000.00 | 05/09/2019 | Serious | |
| Penalty | Z: Issued | 04/11/2019 | $0.00 | 05/09/2019 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: a) On or about November 5, 2018, the Press Brake Operator of the AccroPress 7608 8 foot 60 Ton Hydraulic Press Brake did not de-energized the Press Brake using lockout/tagout procedures, install the die block or utilize the Press Brake Control System to prevent motion of the Press Brake ram while changing dies.
Translate