Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1498399.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,192.00
Current Penalty: $0.00
Issuance Date: 04/09/2021
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 07/01/2021
Gravity: 5
Report ID: 0523300
Contest Date:
Final Order: 05/03/2021
Related Event Code (REC): A;R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/03/2021 | $0.00 | 07/01/2021 | Serious | |
| Penalty | Z: Issued | 04/09/2021 | $8,192.00 | 04/23/2021 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about October 13, 2020, the lockout/tagout procedure for sheetfed printing presses was not performed in sequence to ensure that the Mitsubishi offset printing press (Serial No. 3F 1885) was shut down and isolated during roller cleaning activities.
Translate