Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1447472.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/18/2019
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/15/2020
Gravity: 5
Report ID: 0316400
Contest Date:
Final Order: 01/15/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/15/2020 | $0.00 | 01/15/2020 | Serious | |
| Penalty | Z: Issued | 12/18/2019 | $0.00 | 01/15/2020 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.212(a)(3)(ii): Point of operation guarding devices were not in conformity with any appropriate standards: (a) Press Department - The orange Pexto Shear had a point of operation guard that was not designed according to industry standards in that the bottom of the guard had a gap of one-half inch and was less than one inch from the shear's blade which would allow an employee's fingers to reach the point of operation. Feasible abatement of this hazard would be to follow industry standards including, but not limited to, American National Standards Institute (ANSI) B11.4 Safety Requirements for Shears which requires a guard to be at a minimum distance of three and a half inches away from the point of operation for a gap opening in the guard of one half inch.