Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1332447.015
Citation: 01001B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/07/2019
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/17/2019
Gravity: 10
Report ID: 0625700
Contest Date:
Final Order: 02/13/2019
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/13/2019 | $0.00 | 01/17/2019 | Serious | |
| Penalty | Z: Issued | 01/07/2019 | $0.00 | 01/17/2019 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: On or about July 10, 2017, at Lost Lake, in the vicinity of Dularge near the Falgout Canal Marina at latitude 29 *20.155N and longitude 091*02.317, the employer did not ensure that energy control procedures clearly outlined steps employees must take to control hazardous energy while performing repairs on a carriage spud ram on a dredge.