Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1318218.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/16/2018
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/13/2018
Gravity: 10
Report ID: 0936100
Contest Date:
Final Order: 12/18/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 11/16/2018 | $0.00 | 12/13/2018 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. AMSA 98 Maintenance Shop: Energy control procedures had not been established by the employer for M-Gator maintenance and repairs. On May 23, 2018, an employee was crushed when the automated lifting mechanism for the cargo box failed and pinned the employee between the bed and the frame.