Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1513505.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,288.00
Current Penalty: $9,216.00
Issuance Date: 07/27/2021
Nr Instances: 2
Nr Exposed: 3
Abatement Date: 08/31/2021
Gravity: 10
Report ID: 0418300
Contest Date:
Final Order: 08/19/2021
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/19/2021 | $9,216.00 | 08/31/2021 | Serious | |
| Penalty | Z: Issued | 07/27/2021 | $12,288.00 | 08/20/2021 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about 01/29/2021 - Fabrication Area, employees were exposed to caught-between hazards due to not utilizing the lockout procedure "Trumpf -Tru-Laser 5030 (A0231A0314)" when performing servicing and maintenance activities such as, but not limited to, adjusting proximity switch sensors on the Trumpf Tru-Laser 5030 Automatic Pallet Changer. (b) On or about 01/29/2021 - Fabrication Area, employees were exposed to caught-between hazards when performing servicing and maintenance activities such as, but not limited to, adjusting proximity switch sensors on the Trumpf Tru-Laser 5030 Automatic Pallet Changer and a procedure had not been developed for controlling potentially hazardous energy due to gravity.