Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1478145.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,494.00
Current Penalty: $13,494.00
Issuance Date: 07/02/2020
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/19/2020
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 09/08/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/08/2020 | $13,494.00 | 08/19/2020 | Serious | |
| Penalty | Z: Issued | 07/02/2020 | $13,494.00 | 08/19/2020 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. On 5/20/2020, at the Murrayville facility, in the Mechanical Debone Department, an Authorized employee did not utilize proper lockout to the floor vacuum valve mechanism and incurred a thumb tip amputation. The employee had not been trained in the specific written procedures for the floor vacuum.
Translate