Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1579115.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $10,876.50
Issuance Date: 03/28/2022
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 04/21/2022
Gravity: 10
Report ID: 0729700
Contest Date:
Final Order: 04/27/2022
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/27/2022 | $10,876.50 | 04/21/2022 | Other | |
| Penalty | Z: Issued | 03/28/2022 | $14,502.00 | 04/21/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about February 17, 2022, set up technician employees engaged in mold and tooling set up activities were exposed to caught-in and/or caught-between hazard in that the specific machine procedures for a complete program rod removal task from the Davis Standard Sterling Extrusion Molding machine #9, Twin 15lb head S#07834 which had multiple energy sources including pneumatic, electrical, hydraulic, and gravity were not developed, documented and utilized.