Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1565227.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $9,324.00
Current Penalty: $4,662.00
Issuance Date: 03/03/2022
Nr Instances: 1
Nr Exposed: 11
Abatement Date:
Gravity: 5
Report ID: 0524700
Contest Date:
Final Order: 03/24/2022
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/24/2022 | $4,662.00 | Serious | ||
| Penalty | Z: Issued | 03/03/2022 | $9,324.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.219(d)(1):Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) GE Lighting Inc. on or about November 22, 2021 at the address of 1250 S. Walnut St. Bucyrus, OH: The employer did not ensure the power transmitting belt and pulley(s) of the direct drive motor for the "Bulb crusher" HS1 coater conveyer was adequately guarded. Following a maintenance and cleaning operation, an employee working on or near this unguarded nip-point was exposed to amputation hazards.