Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1525757.015
Citation: 01001
Citation Type: Serious
Abatement Status: Quick Fix
Initial Penalty: $5,969.00
Current Penalty: $5,969.00
Issuance Date: 07/16/2021
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 5
Report ID: 0316400
Contest Date:
Final Order: 08/12/2021
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 07/16/2021 | $5,969.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by: (a)P-Line Extruder; On or about April 13, 2021, employees worked on and around the feeder transition piece of the extruder. The butterfly valve near the end of the feeder transition piece was not properly guarded and allowed employees to come in contact with the valve when dislodging the polytubing from the inside of the transition piece.