Violation Detail
Standard Cited: 19261053 B12 Ladders.
Inspection Nr: 1508021.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,487.00
Current Penalty: $1,865.25
Issuance Date: 02/17/2021
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 03/15/2021
Gravity: 5
Report ID: 0830100
Contest Date:
Final Order: 03/08/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/08/2021 | $1,865.25 | 03/15/2021 | Serious | |
| Penalty | Z: Issued | 02/17/2021 | $2,487.00 | 03/15/2021 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.1053(b)(12):Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive side rails: a)18934 Lone Wolf, Huson, MT: On or about December 22, 2020, employees were exposed to electrocution hazards while installing snow stops on a residential metal roof using a 24 foot Werner aluminum ladder near power lines. An employee was electrocuted when the aluminum ladder came into contact with the power lines during the installation operations.
Translate