Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1503408.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $9,639.00
Current Penalty: $4,819.50
Issuance Date: 01/15/2021
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 06/01/2021
Gravity: 5
Report ID: 0625400
Contest Date:
Final Order: 04/20/2021
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/20/2021 | $4,819.50 | 06/01/2021 | Other | |
| Penalty | Z: Issued | 01/15/2021 | $9,639.00 | 01/28/2021 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about November 13, 2020, one employee was performing a double belt change for an exhaust fan located on the roof without equipment specific lockout/tagout procedures being developed and utilized, exposing the employee to the hazard of being caught in the belt and pulley.