Standard Cited: 19100147 D05 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1434174.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,260.00
Current Penalty: $10,000.00
Issuance Date: 02/25/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 03/13/2020
Gravity: 10
Report ID: 0419700
Contest Date:
Final Order: 03/12/2020
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/12/2020 | $10,000.00 | 03/13/2020 | Serious | |
| Penalty | Z: Issued | 02/25/2020 | $13,260.00 | 03/13/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: a. On or about September 25, 2019, stored energy was not relieved or restrained and the 125 Log Crane was not rendered safe after the application of lockout devices, exposing two employees to amputation and crushing hazards.