Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1219957.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/05/2017
Nr Instances: 1
Nr Exposed: 7
Abatement Date: 09/26/2017
Gravity:
Report ID: 0627100
Contest Date:
Final Order: 09/29/2017
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 09/05/2017 | $0.00 | 09/26/2017 | Other |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: On or about March 10, 2017, and times prior to, written certification was not maintained for the annual inspections of energy control procedures for equipment such as but not limited to the Saw Dust Feeder located in Department 545.
Translate