Violation Detail
Standard Cited: 19260451 A06 General requirements.
Inspection Nr: 1209687.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,873.00
Current Penalty: $4,436.50
Issuance Date: 04/20/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 05/09/2017
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 05/03/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/03/2017 | $4,436.50 | 05/09/2017 | Serious | |
| Penalty | Z: Issued | 04/20/2017 | $8,873.00 | 05/09/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.451(a)(6): Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. On February 10, 2017, located on the North Wing of area D23, employees were exposed to fall hazards while performing masonry work from a tubular welded frame scaffold without the use of snap pins installed to support the adjustable saddle hanger to the frame of the scaffolding system per manufacture design. Potential fall height measured to be 23.6 feet. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.