Accident Report Detail
Accident Summary Nr: 774489 - Employee killed by fall down elevator shaft
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 123542789 | 04/05/1994 | 1541 | 0 | Younglove Construction Co |
Abstract: Employee #1 was working atop an elevator cage installing cables at the top of an elevator shaft. The elevator cage was secured by a come-along and a hand winch. Employee #1 removed the winch and the come-along, thinking the emergency brakes would hold the cage. He was not wearing a safety belt with secured lifeline. The elevator fell and Employee #1 fell 185 ft to his death.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 123542789 | Fatality | Other | Occupation not reported |
Translate