Accident Report Detail
Accident Summary Nr: 202675971 - Employee Amputates Fingertip in Machine
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 317248821 | 01/23/2014 | 2044 | 311212 | Farmers' Rice Cooperative |
Abstract: On January 15, 2014, Employee #1 was operating a machine that would remove the bran from rice, making the rice completely white in color. The machine was a 75-hp Satake Rice Whitener (Model Number VBF-10A-L). While the machine was running, she reached into its exhaust side to remove the buildup of bran that had accumulated in the plumbing. The machine was not locked out and used fan blades to debran the rice. The blades were spinning and approximately 12 in. from where she was cleaning. Employee #1 made contact with the blade or was struck by something dislodged from the blade that amputated her fingertip. She was transported to the local urgent care and then transferred to a general hospital for surgery, after which she was hospitalized and released the following morning.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 317248821 | Hospitalized injury | Amputation | Laborers, except construction |
Translate