Accident Report Detail
Accident Summary Nr: 202503629 - Employee Is Injured in Truck Collision
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 311361976 | 10/30/2007 | 4813 | 517310 | Verizon Maryland, Inc. |
Abstract: On October 30, 2007, Employee #1, a Verizon telephone repairman, was soldering the telephone line at pole # M2582, to repair an air pressure leak. Employee #1 had parked the Verizon truck in the roadway facing east bound in the west bound lane. The basket of the lift was 13 ft. above the sidewalk. A privately owned F-350 Ford truck was traveling west bound and hit the Verizon truck head on. The impact of the collision caused the bucket and boom to strike the telephone pole, detaching the bucket from the boom. Employee #1 and the bucket fell approximately 14 ft. to the ground. The attachment point for the fall protection on this equipment was located on the end of the boom. Employee #1's lanyard and belt was still attached to the boom after the accident. Employee #1 was hospitalized overnight and released the next day. Employee #1's injuries included a fractured pelvis, broken ribs a broken tooth and bruises.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 311361976 | Hospitalized injury | Fracture | Telephone line installers and repairers |