Accident Summary Nr: 200555910 - Employee Is Killed When Struck by Falling Crane
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 313027781 | 11/17/2009 | 1799 | 238190 | Moreau'S Material Yard |
Abstract: On November 17, 2009, employees with Moreau's Material Yard were driving pilings for an oil rig foundation in which a 4,000 lb hammer, attached to the top of the lead, was used to drive 70 to 75 ft poles into the ground. Employee #1 was working on a crawler crane platform approximately 20 to 25 ft above the ground. He was wearing a harness with a lanyard connected to a ladder rung. When the crane tipped over, Employee #1 attempted to jump from the platform to the ground below. He was struck by the crane and killed. The crane operator sustained minor injuries. Other employees indicated that the employer had never lifted poles of that size and the crane boom may have been used at an improper angle for the load being carried.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Other heavy construction | New project or new addition | $50,000 to $250,000 | 1 | X | |||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 313027781 | Fatality | Other | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pile driving Fatality Cause: Struck by falling object/projectile |