Accident Report Detail
Accident Summary Nr: 200532745 - Employee Is Killed by Falling Steel Column
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 312768351 | 11/13/2008 | 1791 | 238120 | S & L Construction |
Abstract: On November 12, 2008, Employee #1 and the coworkers were involved in the construction of steel columns at the ground level. Employee #1 and the coworkers guided and set 24-ft steel columns into four 0.75-in. rebar stakes, raising them 2 in. above the concrete ground. Employee #1 set a pair of washers and nuts on the rebar to secure the column. One coworker used a powered industrial vehicle with a strap to lower the steel column vertically, and another coworker used a scissors lift to remove the strap from the steel column, once it was set. When Employee #1 put a pair of washers and nuts on column, his coworker prematurely removed the strap from the steel column, before the column was properly braced. As a result of this action, the steel column lifted off the back side rebars, causing the front rebars to bend, and the others to sheer off. The steel column fell on Employee #1 and killed him.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Other building | New project or new addition | $500,000 to $1,000,000 | 1 | 25 | X | ||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 312768351 | Fatality | Concussion | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Erecting structural steel Fatality Cause: Collapse of structure |