Accident Report Detail
Accident Summary Nr: 169717.015 - Employee dies when electrocuted while welding elevated pipe
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1772386.015 | 08/29/2024 | 213112 | M.P.G. Pipeline Contractors, Llc |
Abstract: At 2:49 p.m. on August 27, 2024, Employee #1 was working at an elevated position welding a 20-inch pipe. The employee was preparing to connect the welding rod to the stinger when he was suddenly shocked. Witnesses reported that the employee's body locked up upon attachment of the rod to the stinger, and they were unable to remove the stinger from his hand until the welding machine was turned off. The employee was electrocuted and later died from the injuries.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Pipeline | Other | 2 | X | ||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 1772386.015 | 28 | M | Fatality | Welders and cutters | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Trenching, installing pipe Fatality Cause: |
Translate