Accident Summary Nr: 167692.015 - Employee dies of CO overexposure and cardiovascular disease
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1757240.015 | 06/18/2024 | 238110 | Hoonhorst Concrete Inc |
Abstract: At 1:30 p.m. on June 17, 2024, an employee working for concrete finishing contractor was operating a shop vacuum in a 125-foot by 125-foot by 30-foot indoor cooler. The employee was working near a coworker who was running a large, self-propelled, gas-powered concrete saw. The employee left the cooler to rest and collapsed in front of the contractor's truck. The employee died from hypertensive and atherosclerotic cardiovascular disease and acute carbon monoxide poisoning.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1757240.015 | 44 | M | Fatality | Concrete and terrazzo finishers |