Accident Report Detail
Accident Summary Nr: 156345.015 - One employee is killed and another employee injures head whe
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1670278.015 | 05/15/2023 | 236220 | Hayes Services, Llc |
Abstract: At 9:00 a.m. on May 14, 2023, Employee #1 and Employee #2 were trying to line up a drive sprocket and chain after replacing the sprocket on a chain driven flight conveyor. Employee #1 was using a a 24-inch pipe wrench on the end of the shaft to offset pressure applied by the system, while Employee #2 changed the direction of the ratchet they were using. Four (4) come-alongs had been applied to the chains that drive the conveyor flights to prevent the conveyor from sliding down an incline. While conducting the work, Employee #2 was struck in the head by the pipe wrench. Employee #1 lost control of the ratchet and the pipe wrench continued to rotate with the shaft and struck and struck Employee #1 in the head. Employee #1 was killed and Employee #2 was hospitalized to treat head injuries.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1670278.015 | 57 | M | Fatality | Millwrights | |
| 2 | 1670278.015 | 27 | M | Hospitalized injury | Millwrights |
Translate