Accident Report Detail
Accident Summary Nr: 14550677 - Employees Washed into River by High Pressure Water
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1528819 | 12/06/1984 | 4911 | 0 | Utah Power & Light Co |
Abstract: A penstock at a hydroelectric plant ruptured at a welded area. The rupture resulted from a water hammer caused by a malfunctioning Johnson valve. Water, escaping at approximately 3,000 cubic feet per second, washed seven vehicles, a 70- by 40-foot building, and the parking lot into the river. Employees #1 through 4, who were in vehicles, drowned, and Employee #5 was injured when he was swept ashore. Employee #5 was hospitalized for his injuries.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1528819 | Fatality | Other | Occupation not reported | ||
| 2 | 1528819 | Hospitalized injury | Strain/Sprain | Occupation not reported | ||
| 3 | 1528819 | Fatality | Other | Occupation not reported | ||
| 4 | 1528819 | Fatality | Other | Occupation not reported | ||
| 5 | 1528819 | Fatality | Other | Occupation not reported |
Translate